CCD vs CMOS SNR calculator
In a 1 s exposure at 10 photons per pixel, a back-illuminated sCMOS (ORCA-Fusion BT, 1.0 e read noise) reaches an SNR of 2.8 against 2.2 for a deep-cooled CCD (iKon-M 934, 2.9 e). Past about 7 s the CCD's near-zero dark current wins: at 60 s it holds 2.2 while the air-cooled sCMOS falls to 1.1.
Winner Hamamatsu ORCA-Flash4.0 V3 C13440-20CU, by 8.054 dB.
A: Hamamatsu ORCA-Flash4.0 V3 C13440-20CU
Stacked SNR: 8.914 / 19 dB
Dynamic range (dB): 85.46
Dynamic range (stops): 14.19
Read-noise-limited signal (electrons): 2.56
B: Kodak (now onsemi) KAI-04050 monochrome ABA
Stacked SNR: 3.527 / 10.95 dB
Dynamic range (dB): 64.44
Dynamic range (stops): 10.7
Read-noise-limited signal (electrons): 144
Crossover (photons/pixel): No crossover in the plotted range
Presets and curve values
| Photons per pixel per exposure | A | B | Ideal shot noise |
|---|---|---|---|
| 0.01 | 0.005058 | 4.069e-4 | 0.1 |
| 0.013 | 0.006572 | 5.289e-4 | 0.114 |
| 0.0169 | 0.008538 | 6.876e-4 | 0.13 |
| 0.02197 | 0.01109 | 8.938e-4 | 0.1482 |
| 0.02856 | 0.0144 | 0.001162 | 0.169 |
| 0.03712 | 0.0187 | 0.00151 | 0.1927 |
| 0.04826 | 0.02426 | 0.001963 | 0.2197 |
| 0.06273 | 0.03147 | 0.002552 | 0.2505 |
| 0.08154 | 0.04079 | 0.003318 | 0.2856 |
| 0.106 | 0.05283 | 0.004312 | 0.3256 |
| 0.1378 | 0.06835 | 0.005606 | 0.3712 |
| 0.1791 | 0.0883 | 0.007286 | 0.4232 |
| 0.2329 | 0.1139 | 0.009471 | 0.4826 |
| 0.3027 | 0.1466 | 0.01231 | 0.5502 |
| 0.3935 | 0.1881 | 0.016 | 0.6273 |
| 0.5115 | 0.2406 | 0.0208 | 0.7152 |
| 0.6649 | 0.3065 | 0.02703 | 0.8154 |
| 0.8644 | 0.3885 | 0.03512 | 0.9297 |
| 1.124 | 0.4896 | 0.04564 | 1.06 |
| 1.461 | 0.613 | 0.05929 | 1.209 |
| 1.899 | 0.7618 | 0.07702 | 1.378 |
| 2.468 | 0.9392 | 0.1 | 1.571 |
| 3.209 | 1.148 | 0.1299 | 1.791 |
| 4.171 | 1.392 | 0.1686 | 2.042 |
| 5.422 | 1.673 | 0.2187 | 2.329 |
| 7.049 | 1.994 | 0.2835 | 2.655 |
| 9.163 | 2.36 | 0.3673 | 3.027 |
| 11.91 | 2.775 | 0.4754 | 3.451 |
| 15.48 | 3.244 | 0.6145 | 3.935 |
| 20.13 | 3.774 | 0.793 | 4.486 |
| 26.17 | 4.373 | 1.021 | 5.115 |
| 34.01 | 5.049 | 1.312 | 5.832 |
| 44.21 | 5.815 | 1.68 | 6.649 |
| 57.48 | 6.682 | 2.144 | 7.581 |
| 74.72 | 7.665 | 2.722 | 8.644 |
| 97.13 | 8.781 | 3.438 | 9.855 |
| 126.3 | 10.05 | 4.314 | 11.24 |
| 164.1 | 11.49 | 5.376 | 12.81 |
| 213.4 | 13.13 | 6.646 | 14.61 |
| 277.4 | 14.99 | 8.148 | 16.65 |
| 360.5 | 17.12 | 9.905 | 18.99 |
| 468.7 | 19.54 | 11.94 | 21.65 |
| 609.3 | 22.29 | 14.27 | 24.68 |
| 792 | 25.43 | 16.93 | 28.14 |
| 1030 | 29.01 | 19.95 | 32.09 |
| 1338 | 33.09 | 23.37 | 36.58 |
| 1740 | 37.74 | 27.23 | 41.71 |
| 2262 | 43.03 | 31.59 | 47.56 |
| 2940 | 49.07 | 36.51 | 54.22 |
| 3822 | 55.96 | 42.08 | 61.82 |
| 4968 | 63.81 | 48.39 | 70.49 |
| 6458 | 72.75 | 55.54 | 80.36 |
| 8396 | 82.96 | 63.66 | 91.63 |
| 10910 | 94.59 | 72.87 | 104.5 |
| 14190 | 107.8 | 83.34 | 119.1 |
| 18440 | 123 | 95.25 | 135.8 |
| 23970 | 140.2 | 108.8 | 154.8 |
| 31170 | 159.9 | 124.2 | 176.5 |
| 40510 | 182.3 | 141.8 | 201.3 |
| 52660 | 207.8 | 161.8 | 229.5 |
| 68460 | 236.9 | 184.6 | 261.7 |
| 89000 | 270.1 | 210.6 | 298.3 |
| 1.157e+5 | 308 | 240.2 | 340.1 |
| 1.504e+5 | 351.2 | 273.9 | 387.8 |
| 1.955e+5 | 400.4 | 312.4 | 442.1 |
| 2.541e+5 | 456.5 | 356.3 | 504.1 |
| 3.304e+5 | 520.5 | 406.2 | 574.8 |
| 4.294e+5 | 593.4 | 463.2 | 655.3 |
| 5.583e+5 | 676.6 | 528.2 | 747.2 |
| 7.257e+5 | 771.4 | 602.2 | 851.9 |
| 9.434e+5 | 879.5 | 686.7 | 971.3 |
| 1.226e+6 | 1003 | 783 | 1107 |
| 1.594e+6 | 1143 | 892.7 | 1263 |
| 2.072e+6 | 1304 | 1018 | 1440 |
| 2.694e+6 | 1486 | 1161 | 1641 |
| 3.502e+6 | 1695 | 1323 | 1871 |
| 4.552e+6 | 1932 | 1509 | 2134 |
| 5.918e+6 | 2203 | 1720 | 2433 |
| 7.693e+6 | 2512 | 1961 | 2774 |
| 1.000e+7 | 2864 | 2236 | 3162 |
What Pro produces
Batch runs over a table of inputs, a PDF report with inputs, method and citations, CSV export and saved cases. Join the waiting list and we will write once, when it opens.
Use this in your AI assistant
This calculator is available to Claude, ChatGPT and other assistants through ScienceShot’s free connector.
https://scienceshot.com/mcpConnector tool: image_sensor_snr
Example: CCD vs CMOS SNR calculator
Presets and curve values
| Sensor | Source document | Readout mode |
|---|---|---|
| Andor iKon-M 934 BV (DU934P-BV) / 0.05 MHz; -80 C; QE up to 95% | iKon-M 934 Series 5 MHz Imaging CCD 1 Megapixel, -100C (specification sheet) | 0.05 MHz; -80 C; QE up to 95% |
| Andor iXon Ultra 888 (#BV option) / EM amplifier 30 MHz; -80 C; QE >95% | iXon Ultra EMCCD specification sheet (footer code iXonUltraSS 0425 R1) | EM amplifier 30 MHz; -80 C; QE >95% |
| Hamamatsu ORCA-Flash4.0 V3 C13440-20CU / Standard scan; -10 C; QE at 560 nm | Technical note: ORCA-Flash4.0 V3 Digital CMOS camera C13440-20CU | Standard scan; -10 C; QE at 560 nm |
| Hamamatsu ORCA-Fusion BT C15440-20UP / Standard scan; -8 C forced air; QE at 550 nm | ORCA-Fusion BT Digital CMOS camera C15440-20UP (Cat. No. SCAS0143E03) | Standard scan; -8 C forced air; QE at 550 nm |
| Teledyne FLIR Blackfly S BFS-U3-51S5M (Sony IMX250) / EMVA 1288; 12-bit ADC; QE at 525 nm | EMVA 1288 Imaging Performance, BFS-U3-51S5 | EMVA 1288; 12-bit ADC; QE at 525 nm |
| Kodak (now onsemi) KAI-04050 monochrome ABA / 40 MHz; photodiode dark current at 40 C; QE at 500 nm | KODAK KAI-04050 Image Sensor, Product Summary | 40 MHz; photodiode dark current at 40 C; QE at 500 nm |
Cite this
ScienceShot. CCD vs CMOS SNR calculator. https://scienceshot.com/ccd-vs-cmos-snr-calculator.
More formats
ScienceShot. (2026). CCD vs CMOS SNR calculator [Online calculator]. https://scienceshot.com/ccd-vs-cmos-snr-calculator
@misc{scienceshot-ccd-vs-cmos-snr-2026,
author = {{ScienceShot}},
title = {{CCD vs CMOS SNR calculator}},
year = {2026},
note = {Online calculator},
url = {https://scienceshot.com/ccd-vs-cmos-snr-calculator}